IntelŪ Server Board STL2
for IntelŪ PentiumŪ III Processors
Powerful, Dual-Processing Server Board for General-Purpose e-Business Applications and Front-End Server Workloads
Features include:
Server Performance for Small and Medium-Size Businesses
The IntelŪ Server Board STL2 is a powerful dual-processor server board for
serious workgroup and e-Business server applications. Designed for environments
with up to 100 users, the STL2 can be configured to meet a variety of server
needs ranging from single-function to multi-function server applications.
Internet-Equipped using IntelŪ Server Technology
The STL2 server board's scalability provides the performance needed for today's
unpredictable e-Business economy. It supports up to two IntelŪ PentiumŪ III
processors with 133 MHz system bus and six PCI slots. Two of the PCI slots are
on an independent, 64-bit/66 MHz PCI bus, which provides added I/O throughput.
Additional server technologies include the IntelŪ PRO/100+ Fast Ethernet
Controller, Ultra160 SCSI storage, 4 GB of PC133 ECC SDRAM memory capacity,
Intel server management, and a three-year limited warranty.
Service, Support, and Three-Year Limited Warranty
Intel provides service options to system integrators and dealers on all Intel
server building blocks1, including a three-year, limited warranty and
next-business-day replacement of in-warranty Intel server products and optional
server spares kits to enable same-day service. In addition, Intel provides
access to support personnel for assistance with technical questions, and
dedicated Web sites such as support.intel.com
and www.intel.com/go/serverbuilder.
1 Some restrictions apply. Not available in all
countries.
| Features | Benefits |
|---|---|
| Supports one to two IntelŪ PentiumŪ III processors operating on a 133 MHz system bus only. For additional details, see: http://support.intel.com/support/motherboards/server | Performance for demanding server applications |
| Supports up to 4 GB of PC133 ECC Registered SDRAM memory, four DIMM sockets | State-of-the-art memory technology and increased capacity to support a wide range of server tasks |
| Six available PCI slots: two 64-bit/66 MHz, and four 32-bit/33 MHz | Investment protection; room to grow with support for high-performance PCI cards; 64/66 PCI provides high performance I/O |
| Dual-Peer PCI Buses | Separate PCI buses reduce data bottlenecks and increase bandwidth for intensive I/O needs |
| Integrated Adaptec* (AIC*7899) dual-channel SCSI controller: one Ultra160 channel and one Ultra Wide channel | Maximum data throughput due to independent SCSI channels |
| Integrated ATI Rage* IIC PCI graphics controller with 4 MB of memory | High-quality integrated video eliminates the need for PCI video card |
| Integrated IntelŪ PRO/100+ Fast Ethernet Controller (IntelŪ 82559) | Scalable network bandwidth and redundant links when combined with Intel's complete line of server adapters |
Server management capabilities:
|
Intel Server Control provides the data protection, physical security, remote access, and quick problem resolution capabilities that used to be available only on high-end server systems |
| Three-year limited warranty | Peace of mind with Intel technology |
IntelŪ Server Board STL2 for IntelŪ PentiumŪ III Processor
Support for Two IntelŪ PentiumŪ III Processors
Advanced IntelŪ Server Management
4 GB PC133 ECC Registered SDRAM Memory Support Four DIMM sockets
IDE Connectors
Integrated SCSI Adaptec* AIC7899 dual-channel SCSI controller One Ultra160 channel One Ultra Wide channel
ServerWorks* ServerSet* III LE Chipset
Integrated Graphics ATI Rage* IIC PCI graphics controller with 4 MB of memory
Dual-Peer PCI, Six Available PCI Slots Bus A-four 32-bit/33MHz PCI slots Bus B-two 64-bit/66MHz PCI slots
Integrated IntelŪ Pro/100+ Server Adapter (IntelŪ 82559 Controller)
Voltage Regulation Module Slot
IntelŪ Server Board STL2 Specifications
| Processor/Cache | |
| Processor Supported | IntelŪ PentiumŪ III processors operating on the 133 MHz system bus only. For the latest processor support, go to: http://support.intel.com/support/motherboards/server |
| Chipset | ServerWorks* ServerSet* III LE |
| System Memory | |
| Memory Capacity | Four DIMM sockets for up to 4 GB of SDRAM (64 MB to 1 GB DIMMs supported) |
| Memory Type | PC/133 Registered SDRAM 72-bit ECC, 168-pin gold-plated DIMMs |
| DIMM Sizes | 64 MB, 128 MB, 256 MB, 512 MB, 1GB |
| Memory Voltage | 3.3V only |
| Error Detection | Corrects single-bit errors, detects double-bit errors (using ECC memory) |
| Expansion Slots | |
| Description | Six dedicated PCI slots (bus mastering) |
| Integrated Adaptec* SCSI Controller | |
| Controller | Adaptec* AIC7899
Dual Channel-one Ultra160/LVD channel, one Ultra Wide channel. Two 68-pin
"wide" SCSI connectors. Max data transfer: 160 MB/sec on Ultra160/LVD channel |
| Integrated IntelŪ Network Adapter | |
| Controller | One IntelŪ
PRO/100+ Fast Ethernet Controller (IntelŪ 82559) Supports 10BASE-T and 100BASE-TX, RJ45 output |
| Integrated Input/Output Controller Hub (ICH) | |
| PCI | Six total: two 64-bit/66MHz, four 32-bit/33MHz |
| IDE | One EIDE channel for a total of two IDE devices backward-compatible to provide CD-ROM |
| USB | Two stacked USB connectors |
| Graphics | |
| ATI Rage* IIC SVGA PCI video controller with 4 MB of video memory | |
| Integrated Super I/O | |
| Controller | National* PC97317 |
| Serial ports | Two asynch, RS-232C, 9-pin and 10-pin |
| Parallel port | IEEE 1284, 25-pin bi-directional |
| Floppy Controller | 1.44 MB, 2.88 MB, 3-mode support |
| Keyboard/mouse | PS/2, 8240A-compatible |
| System BIOS | |
| BIOS Type | 8 Mb Flash EEPROM with Phoenix* BIOS, Multi-boot BBS (BIOS Boot Specification) 1.4-compliant |
| Special Features | Plug and Play, IDE drive auto-configure, SMBios 2.3, ECC/Parity support, multilingual support |
| Configuration Utilities | System Set-up Utility (SSU) enables easy system setup of BIOS and utilities, Plug and Play |
| Jumpers and Front Panel Connectors | |
| Front Panel Connectors | Power LED, power on/off switch, reset |
| Jumpers | CMOS clear, password clear, processor frequency setting |
| Mechanical | |
| Server Board Style | SSI, fits in many ATX 2.x-compliant tower chassis |
| Server Board Size | 12" x 11.5" |
| Server Board Power Requirements | |
| +5V | 21.73A maximum continuous current |
| +5V Standby | .78A minimum continuous current |
| +12V | 4.06A maximum continuous current |
| +3.3V | 14.18A maximum continuous current |
| -5V | 0 maximum continuous current |
| -12V | .02A maximum continuous current |
| Server Management Instrumentation3 | |
| Failure Detection | Voltage, thermal, operating-system, watchdog fan failure, hard disk drive failure, power supply failure, processor status, ECC memory, heat-sink fan check |
| Platform Event Paging | Paging on hardware events (external modem required) |
| Event Logging | Non-volatile storage to prevent loss of logs in the event of system or power failure |
| Security | Chassis intrusion detection, video blanking, password protection |
| IntelŪ Server Control (ISC), Version 2.x | |
| Managed Server | Operating systems
supported: Microsoft Windows* 2000 Microsoft Windows* NT* Server 4.0 Novell NetWare* 4.2, 5.0 SCO UnixWare* 7.1 Red Hat Linux* 6.2 |
| Management Consoles Supported | ISC integrates into
the leading management consoles: IntelŪ LANDeskŪ Server Manager 6.04 HP OpenView* Network Node Manager 5.02 for Microsoft Windows* NT CA TNG* Framework 2.02 for Microsoft Windows* NT |
| Alert Notification | Methods of notification are available: Network broadcast, SNMP trap, writing into server OS log, writing into system event log (non-volatile storage), message box |
| Critical Event Actions | In response to user-configurable event thresholds, graceful operating system shutdown, with reboot or power-off, at administrator's discretion: Immediate power-off or reset |
| Environment | |
| Ambient Temperature4 | Operating (system)
+10°C to +35°C Non-operating/storage (system) -40°C to + 70°C ambient |
| Relative Humidity | Non-operating 95%, non-condensing @ 30°C |
| Product Regulations | |
| Safety Compliance: | |
| U.S. & Canada | UL/CUL 950-CSA 950 (UL Recognition Mark) |
| Europe | EN60950, CE Mark-EU Directive 73/23/EEC |
| Russia | EN60950 (GOST-R Mark) |
| International | IEC60950 |
| EMI Verification - configured in a compatible5 Intel host system | |
| U.S. | Verified to FCC, Class A |
| Canada | Verified to ICES-003, Class A |
| Europe | Verified to EN55022 (Class A) and EN55024 (CE Mark-EU Directive 89/336/EEC) |
| Russia | Verified to EN55022, EN55024 (GOST-R Mark) |
| International/Japan | Verified to CISPR-22/VCCI, Class A |
| Australia/New Zealand | Verified to AS/NZS 3548, Class A (C-tick Mark) |
Intel Order Code
Server Board STL2 : STL2
3 Full utilization of some server management
features is dependent on the use of an IntelŪ server chassis.
4 Environment ambient temperature measurements are system
measurements with an IntelŪ STL2 board installed in an IntelŪ SC5000 chassis.
5 Compatible host system denotes the system(s) Intel tested the board
in and found it compliant. Regulatory certifications were obtained under the
reference: STL2 and/or 133-xxxxxxx.
![]()
777 S. Central Expressway
Suite 1-S
Richardson, Texas 75080
(972) 994-9404
webmaster@flexcomp.com
Last Updated October 30, 2001